Spécifications
| Classification de technologie de pompe à vide | Diffusion Pump |
| Connection Inlet / Outlet Flange | DN 320 ISO-F / DN 160 ISO-F |
| Méthode de refroidissement | Refroidissement par eau |
| Puissance totale nominale | 6000.00 |
| Tension d'alimentation | 3Ph 380-440V |
18B4B - Pompe à diffusion à vapeur d'huile, 3Ph 380-440V No Monitoring
Variantes
Explorez les variantes ci-dessous pour comparer le produit.
| Short Description | Référence produit | Variante de surveillance du niveau d'huile |
|---|---|---|
| B06510200 | No Monitoring | |
| B06510220 | No Monitoring | |
| B06510240 | No Monitoring | |
| B06510380 | No Monitoring | |
| B06510440 | No Monitoring | |
| B06510480 | No Monitoring | |
| B06511200 | Temperature Monitoring | |
| B06511220 | Temperature Monitoring | |
| B06511240 | Temperature Monitoring | |
| B06511380 | Temperature Monitoring | |
| B06511440 | Temperature Monitoring | |
| B06511480 | Temperature Monitoring | |
| B06512200 | Oil Level Monitoring | |
| B06512220 | Oil Level Monitoring | |
| B06512240 | Oil Level Monitoring | |
| B06512380 | Oil Level Monitoring | |
| B06512440 | Oil Level Monitoring | |
| B06512480 | Oil Level Monitoring | |
| B06513200 | Temperature & Oil Level Monitoring | |
| B06513220 | Temperature & Oil Level Monitoring | |
| B06513240 | Temperature & Oil Level Monitoring | |
| B06513380 | Temperature & Oil Level Monitoring | |
| B06513440 | Temperature & Oil Level Monitoring | |
| B06513480 | Temperature & Oil Level Monitoring | |
| B06520200 | No Monitoring | |
| B06520220 | No Monitoring | |
| B06520240 | No Monitoring | |
| B06520380 | No Monitoring | |
| B06520440 | No Monitoring | |
| B06520480 | No Monitoring | |
| B06521200 | Temperature Monitoring | |
| B06521220 | Temperature Monitoring | |
| B06521240 | Temperature Monitoring | |
| B06521380 | Temperature Monitoring | |
| B06521440 | Temperature Monitoring | |
| B06521480 | Temperature Monitoring | |
| B06522200 | Oil Level Monitoring | |
| B06522220 | Oil Level Monitoring | |
| B06522240 | Oil Level Monitoring | |
| B06522380 | Oil Level Monitoring | |
| B06522440 | Oil Level Monitoring | |
| B06522480 | Oil Level Monitoring | |
| B06523200 | Temperature & Oil Level Monitoring | |
| B06523220 | Temperature & Oil Level Monitoring | |
| B06523240 | Temperature & Oil Level Monitoring | |
| B06523380 | Temperature & Oil Level Monitoring | |
| B06523440 | Temperature & Oil Level Monitoring | |
| B06523480 | Temperature & Oil Level Monitoring | |
| B06530200 | No Monitoring | |
| B06530220 | No Monitoring | |
| B06530240 | No Monitoring | |
| B06530380 | No Monitoring | |
| B06530440 | No Monitoring | |
| B06530480 | No Monitoring | |
| B06531200 | Temperature Monitoring | |
| B06531220 | Temperature Monitoring | |
| B06531240 | Temperature Monitoring | |
| B06531380 | Temperature Monitoring | |
| B06531440 | Temperature Monitoring | |
| B06531480 | Temperature Monitoring | |
| B06532200 | Oil Level Monitoring | |
| B06532220 | Oil Level Monitoring | |
| B06532240 | Oil Level Monitoring | |
| B06532380 | Oil Level Monitoring | |
| B06532440 | Oil Level Monitoring | |
| B06532480 | Oil Level Monitoring | |
| B06533200 | Temperature & Oil Level Monitoring | |
| B06533220 | Temperature & Oil Level Monitoring | |
| B06533240 | Temperature & Oil Level Monitoring | |
| B06533380 | Temperature & Oil Level Monitoring | |
| B06533440 | Temperature & Oil Level Monitoring | |
| B06533480 | Temperature & Oil Level Monitoring |
Pompes à diffusion
Vacuum diffusion pumps are essential for creating high-vacuum environments in various industrial and research applications. They operate by heating a special lubricant (often silicone oils) to produce a high-speed jet of vapour, which directs gas molecules towards the pump’s exhaust. This process allows the pump to achieve very low pressures. They require a mechanical fore vacuum pump to operate.
Booster à vapeur d'huile
Vacuum vapour booster pumps are designed to enhance the performance of vacuum systems by providing high pumping speeds at intermediate pressures, bridging the gap between mechanical boosters and traditional diffusion pumps. These pumps work by using vapour jets to capture and compress gas molecules, effectively increasing the overall efficiency of the vacuum system.
18B4B
The Edwards 18B4B vapour booster pumps offer higher pumping speeds, of up to 6000 l/s at pressures intermediate between mechanical boosters and diffusion pumps. Vapour boosters from Edwards have been proven in the field for over 30 years. With a constant program of updates and modernisation, with input from OEM’s and end users, combined with inherent reliability, ease of use and tolerance to various inlet and exhaust pressures they have been used extensively in metallurgy and coating industries as well as other specialist applications.
Features and Benefits
- Higher Pumping speed in mid vacuum range
- Simple to operate and long service life
- Suitable for harsh duties as they are tolerant to dust and dirt
- Industry proven with large installed base
Informations générales sur le produit
| Bride d'entrée de connexion | DN 320 ISO-F |
| Poids | 175.00 |
| Bride de sortie de connexion | DN 160 ISO-F |
| Taux de fuite | 1.000 × 10⁻⁶ |
| Phase d'alimentation | 3-Ph |
| Tension d'alimentation | 3Ph 380-440V |
| Dimension Longueur | 1.54 |
| Dimension Hauteur | 1.88 |
| Dimension Largeur | 0.625 |
| Méthode de refroidissement | Refroidissement par eau |
| Refroidissement de la connexion | BSPT 1/2" femelle |
| Connection Inlet / Outlet Flange | DN 320 ISO-F / DN 160 ISO-F |
| Dimension Comments | Les dimensions longueur, largeur et hauteur représentent la forme extérieure de ce produit dans son orientation typique, lorsqu'il est posé au sol. Nous recommandons toujours de vérifier les dimensions détaillées données dans les dessins 2D du manuel d'instructions ou les formes 3D données dans les modèles 3D. |
Données de performance
| Puissance totale nominale | 6000.00 |
| Puissance totale nominale @60Hz | 6000.00 |
| Puissance totale nominale @50Hz | 6000.00 |
| Pression ultime | 0.010 |
| Puissance à l'Atmosphère | 6000.00 |
| Pumping Speed Air Nitrogen (@50Hz or max @default setting) | 4.00 |
| Durée de préchauffage | 3600.00 |
| Vitesse de pompage de l'hélium < 10-4 mbar | 6.00 |
| Pression d'appui Max | 260.00 |
| Vitesse de pompage de l'azote dans l'air < 10-4 mbar | 4.00 |
| Consommation électrique Max | 6000.00 |
Conditions d'utilisation - Restrictions
| Pression absolue Entrée Continue Max | 1.300 × 10⁵ |
| Altitude max. | 1000.00 |
| Capacité d'huile min. | 6.000 × 10⁻³ |
| Capacité d'huile max. | 0.010 |
| Pression absolue Sortie Continue Max | 260.00 |
Conditions environnementales
| Température ambiante de fonctionnement max. | 313.15 |
| Température ambiante de stockage min. | 293.15 |
| Température ambiante de stockage max. | 303.15 |
Matériau de construction
| Matériaux de construction | Acier doux nickelé, Aluminium anodisé, Fluoroélastomère, Nitrile, Cuivre, Fibre d'aramide dans un liant en caoutchouc nitrile, Fibre de carbone dans un liant en caoutchouc nitrile |
| Matériaux exposés au vide | Acier doux nickelé, Fluoroélastomère |
| Matériau du Rotor | Acier doux plaqué Ni |
| Matériau du Stator | Aluminium |
Classification
| Classification de la plage de pression du produit | High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar |
| Classification pompe à vide haute/moyenne/primaire | Pompe à vide élevé |
| Classification de pompe sèche ou humide | Wet |
| Classification de technologie de pompe à vide | Diffusion Pump |
Lubrifiants
| Type d'huile par défaut | Edwards201 Vapour Booster Fluid |
Variantes
| Variante de surveillance du niveau d'huile | No Monitoring |
- B06510886 - Instructions.pdf - Dutch - Instructions
- B06510880 - Instructions.pdf - English - Instructions
- B06503840 - Installation.pdf - English - Instructions
- B06599840 - Instructions.pdf - English - Instructions
- B06403840 - Instructions.pdf - English - Instructions
- 301337894_A_E2S 5 & E2S 12.pdf - English - Instructions
- MT91E001 - Instructions.pdf - English - Instructions
- B30301880 - Instructions.pdf - English - Instructions
- B06510883 - Instructions.pdf - French - Instructions
- B06510882 - Instructions.pdf - German - Instructions
- B06510884 - Instructions.pdf - Italian - Instructions
- MT36J0F1 - Instructions.pdf - Japanese - Instructions
- MT91J001 - Instructions.pdf - Japanese - Instructions
- B06510857 - Instructions.pdf - Russian - Instructions
- B06510846 - Instructions.pdf - Simplified Chinese - Instructions
| Titre du produit | Référence | Prix | Ajouter au panier |
|---|---|---|---|
| Protection de la chaudière Interrupteur thermique, B06401113 | B06401113 | EUR 1,189.00 | |
| THERMAL SNAP SWITCH DIFF PUMP, B02302000 | B02302000 | EUR 207.00 |
| Titre du produit | Référence | Prix | Ajouter au panier |
|---|---|---|---|
| Santovac 5 - Vacuum Pump Oil, 1 x 0.5 l, H11401002 | H11401002 | EUR 3,732.00 | |
| Santovac 5 - Vacuum Pump Oil, 1 x 0.1 l, H11401001 | H11401001 | EUR 977.00 |